Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.432
Filtrar
1.
Am J Infect Control ; 51(7): 772-778, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36130627

RESUMEN

BACKGROUND: Alcohol is perceived to aid flexible endoscope channel drying, however we previously showed alcohol increased the time required to dry some channels with forced air versus water alone. Yet, alcohol may prevent microorganism outgrowth during storage. Drying endoscope channels has been shown to prevent outgrowth, but it is unknown if incomplete drying (<10 µL remaining) provides similar protection. METHODS: Endoscope channel test articles were used to determine the efficacy of 70%-30% alcohol flush for prevention of Pseudomonas aeruginosa outgrowth and drying efficiency. For non-alcohol flushed channels, the impact of forced air drying on outgrowth of P. aeruginosa was determined. RESULTS: Alcohol flush (70%-30%) prevented outgrowth with little to no recovery of P. aeruginosa during ambient storage. 70% alcohol increased channel drying time by 1.5 or 3-fold compared to 50% alcohol or water, respectively. Forced air drying of non-alcohol flushed channels greatly reduced the initial contamination level and prevented outgrowth. Incomplete drying of contaminated channels was akin to no application of forced air. Applying forced air for more time than necessary to remove residual liquid did not completely eliminate the low level recovery of P. aeruginosa. CONCLUSIONS: Flushing with reduced concentrations of alcohol may provide a strategy to prevent microbial outgrowth while reducing drying time.


Asunto(s)
Desinfección , Endoscopios , Desinfección/métodos , Desinfección/normas , Endoscopios/microbiología , Contaminación de Equipos/prevención & control , Pseudomonas aeruginosa/efectos de los fármacos , Pseudomonas aeruginosa/crecimiento & desarrollo , 2-Propanol/farmacología , Antiinfecciosos/farmacología , Aire , Factores de Tiempo
2.
Biomed Environ Sci ; 35(11): 992-1000, 2022 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-36443252

RESUMEN

Objective: To investigate the baseline levels of microorganisms' growth on the hands of anesthesiologists and in the anesthesia environment at a cancer hospital. Methods: This study performed in nine operating rooms and among 25 anesthesiologists at a cancer hospital. Sampling of the hands of anesthesiologists and the anesthesia environment was performed at a ready-to-use operating room before patient contact began and after decontamination. Results: Microorganisms' growth results showed that 20% (5/25) of anesthesiologists' hands carried microorganisms (> 10 CFU/cm 2) before patient contact began. Female anesthesiologists performed hand hygiene better than did their male counterparts, with fewer CFUs ( P = 0.0069) and fewer species ( P = 0.0202). Our study also found that 55.6% (5/9) of ready-to-use operating rooms carried microorganisms (> 5 CFU/cm 2). Microorganisms regrowth began quickly (1 hour) after disinfection, and increased gradually over time, reaching the threshold at 4 hours after disinfection. Staphylococcus aureus was isolated from the hands of 20% (5/25) of anesthesiologists and 33.3% (3/9) of operating rooms. Conclusion: Our study indicates that male anesthesiologists need to pay more attention to the standard operating procedures and effect evaluation of hand hygiene, daily cleaning rate of the operating room may be insufficient, and we would suggest that there should be a repeat cleaning every four hours.


Asunto(s)
Anestesiólogos , Higiene de las Manos , Femenino , Humanos , Masculino , Anestesia , Anestesiólogos/estadística & datos numéricos , Desinfección/normas , Higiene de las Manos/normas , Higiene de las Manos/estadística & datos numéricos , Infecciones Estafilocócicas , Quirófanos/normas , Quirófanos/estadística & datos numéricos , Staphylococcus aureus/aislamiento & purificación
3.
Comput Math Methods Med ; 2022: 6916212, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35265173

RESUMEN

Background: In daily inspection, the nonstandard management of sterile articles in clinical departments of hospitals often leads to the destruction of the sterilization effectiveness of sterile articles. Therefore, it is necessary to strengthen governance and improve this phenomenon. This study intends to investigate the mode in which the disinfection supply center participates in the supervision and management of the management of sterile items in clinical departments. It played a role in improving the standardization of the management of sterile articles in clinical departments and ensured the closed-loop management of the sterilization effectiveness of sterile articles. Methods: Every quarter, the disinfection supply center of our hospital will inspect the standardized management of sterile articles in all clinical departments of the hospital, mainly including the storage environment and facilities of sterile articles, the cleanliness of storage cabinets, placement principles, whether they are stored by category, and the quality and validity management of sterile articles. The quarterly inspection results were summarized and analyzed to find the existing problems and the causes. The disinfection supply center shall supervise the improvement. After the disinfection supply center inspected the standardized management of sterile articles in all clinical departments of the hospital for the first time according to the inspection contents, under the guidance and assistance of the nursing department and the hospital infection department, it improved the sterile article management system, conducted knowledge training for the whole hospital, and incorporated the standardized management of clinical sterile articles into the quality control inspection of the nursing department. In the later stage, the disinfection supply center is responsible for conducting routine inspection and supervision on the standardized management of sterile articles in all clinical departments of the hospital every quarter according to the inspection contents, including summarizing, analyzing, and urging the clinical departments to achieve the improvement of the management of sterile articles in clinical departments. Results: The standardization of aseptic articles after improvement was significantly higher than before and during improvement, and the qualified rate was significantly different (99.4% vs 97.9% vs 89.5%, P < 0.05). The average number of lost packages caused by nonstandard management in the department was significantly reduced. The average rate of lost sterile packages during and after the improvement was significantly lower than that before the improvement (10.5% vs 97.9% vs 89.5%, P < 0.05). It also effectively reduced the cost caused by the loss of sterile packages. Conclusion: The disinfection supply center participates in the quality control and management of sterile articles in the nursing department and regularly inspects and supervises the management of sterile articles in clinical departments. It can effectively improve the standardized management of sterile articles in clinical departments, ensure the safety of sterile articles, and form a closed loop of sterilization effectiveness.


Asunto(s)
Desinfección/organización & administración , Desinfección/normas , Departamentos de Hospitales/organización & administración , Departamentos de Hospitales/normas , Central de Suministros en Hospital/organización & administración , Central de Suministros en Hospital/normas , China , Biología Computacional , Humanos , Esterilización/organización & administración , Esterilización/normas
4.
Vet Microbiol ; 262: 109240, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34600200

RESUMEN

Because contaminated livestock trailers are a significant risk for transmitting viruses between herds, various methods of washing, disinfecting, and thermo-assisted drying and decontamination (TADD) have been evaluated for their effectiveness in inactivating porcine reproductive and respiratory syndrome virus (PRRSV) on contaminated surfaces. Information on when to expect negative qRT-PCR results after adequate trailer sanitation is lacking. The objective of this study was to evaluate whether there are conditions associated with washing-disinfectant-TADD procedures that will consistently produce a negative qRT-PCR result for the purpose of monitoring compliance with trailer sanitation and decontamination protocols for PRRSV on metal surfaces. 144 diamond plate aluminum coupons were spiked with PRRSV or phosphate-buffered saline (PBS) and treated with a designated disinfectant protocol. Disinfectants evaluated included multiple accelerated® hydrogen peroxide (AHP) disinfectants and a quaternary ammonium and glutaraldehyde combination disinfectant. Disinfectant was applied for 5 or 60 minutes of contact time at either 20 °C or -10 °C in a matrix of feces or PBS. All coupons were heated until the surface temperature of the coupon reached 71 °C and then held for 10 minutes to simulate TADD under field conditions. Post-treatment swabs for all treatment groups, except negative control groups, were positive by PRRSV qRT-PCR. Under the conditions evaluated in this study, consistently negative qRT-PCR results after treatments were not found. Therefore, for the purpose of monitoring compliance with trailer sanitation and decontamination protocols for PRRSV, alternatives to qRT-PCR should be explored.


Asunto(s)
Descontaminación , Desinfección , Microbiología Industrial , Metales , Virus del Síndrome Respiratorio y Reproductivo Porcino , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Animales , Descontaminación/normas , Desecación , Desinfectantes/farmacología , Desinfección/normas , Calor , Microbiología Industrial/métodos , Microbiología Industrial/normas , Virus del Síndrome Respiratorio y Reproductivo Porcino/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/veterinaria , Porcinos
5.
J Infect Dev Ctries ; 15(9): 1252-1256, 2021 09 30.
Artículo en Inglés | MEDLINE | ID: mdl-34669592

RESUMEN

INTRODUCTION: The COVID-19 pandemic highlights the role of environmental cleaning in controlling infection transmission in hospitals. However, cleaning practice remains inadequate. An important component of effective cleaning is to obtain feedback on actual cleaning practice. This study aimed to evaluate the cleaning process quality from an implementation perspective. METHODOLOGY: An observational study was conducted in a tertiary public hospital in Wuhan, China and 92 cleaning processes of units housing patients with multidrug-resistant organism infections were recorded. The bed unit cleaning quality and floor cleaning quality were measured by six and five process indicators respectively. Descriptive statistics were used to describe the cleaning quality. RESULTS: For bed unit cleaning quality, the appropriate rates of cleaning sequence, adherence to cleaning unit principle, use of cloth, use of cloth bucket, separation of clean and contaminated tools, and disinfectant concentration were 35.9%, 71.7%, 89.7%, 11.5%, 65.4%, and 48.7%, respectively. For floor cleaning quality, the appropriate rates of adherence to cleaning unit principle, use of cloth, use of cloth bucket, separation of clean and contaminated tools, and disinfectant concentration were 13.4%, 50.0%, 35.5%, 11.0%, and 36.7%, respectively. CONCLUSIONS: The cleaning staff showed poor environmental cleaning quality, especially the floor cleaning quality. The findings can help reveal deficiencies in cleaning practices, raise awareness of these deficiencies, and inform targeted strategies to improve cleaning quality and hospital safety.


Asunto(s)
Desinfección/métodos , Control de Infecciones/métodos , China , Infección Hospitalaria/prevención & control , Estudios Transversales , Desinfección/normas , Farmacorresistencia Bacteriana Múltiple , Adhesión a Directriz/estadística & datos numéricos , Hospitales Públicos , Hospitales de Enseñanza , Control de Infecciones/normas , Centros de Atención Terciaria
6.
Antimicrob Resist Infect Control ; 10(1): 133, 2021 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-34507617

RESUMEN

OBJECTIVES/PURPOSE: High-touch surfaces are a critical reservoir in the spread of nosocomial infections. Although disinfection and infection control protocols are well developed, they lack the ability to passively reduce the pathogenic load of high-touch surfaces. Copper and its alloys have been suggested as a surface that exhibit continuous biocidal effects. Antimicrobial studies on these surfaces are prevalent, while virucidal studies are not as well explored. The goal of this study was to first determine the virucidal activity of a copper-nickel-zinc alloy and to then examine the effect of soiling and virus preparation on virucidal activity. METHODS: A baculovirus vector was used as an easily quantifiable model of an infectious enveloped animal cell virus. Droplets containing virus were deposited on surfaces and allowed to stay wet using humidity control or were dried onto the surface. Virus was then recovered from the surface and assayed for infectivity. To examine how the composition of the droplet affected the survival of the virus, 3 different soiling conditions were tested. The first two were recommended by the United States Environmental Protection Agency and the third consisted of cell debris resulting from virus amplification. RESULTS: A copper-nickel-zinc alloy was shown to have strong virucidal effects for an enveloped virus. Copper, nickel, and zinc ions were all shown to leach from the alloy surface and are the likely cause of virucidal activity by this surface. Virucidal activity was achieved under moderate soiling but lost under high soiling generated by routine virus amplification procedures. The surface was able to repeatably inactivate dried virus droplets under moderate soiling conditions, but unable to do so for virus droplets kept wet using high humidity. CONCLUSION: Ion leaching was associated with virucidal activity in both wet and dried virus conditions. Soiling protected the virus by quenching metal ions, and not by inhibiting leaching. The composition of the solution containing virus plays a critical role in evaluating the virucidal activity of surfaces and surface coatings.


Asunto(s)
Antivirales/administración & dosificación , Infección Hospitalaria/prevención & control , Infección Hospitalaria/virología , Desinfección/métodos , Virosis/prevención & control , Aleaciones/farmacología , Aleaciones/uso terapéutico , Antivirales/farmacología , Cobre/farmacología , Cobre/uso terapéutico , Medios de Cultivo Condicionados , Desinfección/normas , Humanos , Técnicas de Dilución del Indicador , Níquel/farmacología , Níquel/uso terapéutico , Virosis/virología , Zinc/farmacología , Zinc/uso terapéutico
7.
Rio de Janeiro; rBLH; 2 rev; set. 2021. [7] p. ilus.(Normas técnicas BLH-IFF/NT, 1, 45). (BLH-IFF/NT 45.21).
Monografía en Español, Portugués | LILACS, BVSAM | ID: biblio-1436556

RESUMEN

Esta Norma Técnica tem por objetivo estabelecer os critérios para lavagem, preparo e esterilização de vidrarias e materiais utilizados nos processos de manipulação e controle da qualidade do leite humano ordenhado, visando a garantia da qualidade em Bancos de Leite Humano e Postos de Coleta de Leite Humano e sua certificação.


Esta Norma Técnica tiene por objetivo establecer los criterios de lavado, preparación y esterilización de la vidriería y materiales utilizados en los procesos de manipulación y control de calidad de la leche humana extraída, con el fin de asegurar la calidad en los Bancos de Leche Humana y Centros de Recolección de Leche Humana y su certificación.


Asunto(s)
Control de Calidad , Esterilización/normas , Desinfección/normas , Bancos de Leche Humana/normas , Vidrio/normas , Leche Humana
8.
Rio de Janeiro; rBLH; 2 rev; set. 2021. [6] p. ilus.(Normas técnicas BLH-IFF/NT, 1, 13). (BLH-IFF/NT 13.21).
Monografía en Portugués | LILACS, BVSAM | ID: biblio-1370914

RESUMEN

Esta Norma Técnica tem por objetivo estabelecer as condições de higiene e conduta de acompanhantes das usuárias e visitantes em Bancos de Leite Humano e em Postos de Coleta de Leite Humano, visando a garantia da qualidade nestes serviços e sua certificação.


Asunto(s)
Humanos , Control de Calidad , Desinfección/normas , Bancos de Leche Humana/normas , Contención de Riesgos Biológicos/normas , Extracción de Leche Materna , Brasil
9.
J Environ Public Health ; 2021: 7682042, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34285698

RESUMEN

Background: The hospital environment, especially surfaces and medical devices, is a source of contamination for patients. Objective: This study carried out, to the best of our knowledge, for the first time at Taza Hospital in Morocco aimed to assess the microbiological quality of surfaces and medical devices in surgical departments and to evaluate the disinfection procedure in time and space. Methods: Samples were taken by swabbing after cleaning the hospital surface or medical device, to isolate and identify germs which were inoculated on semiselective culture media then identified by standard biochemical and physiological tests, using the analytical profile index (API) galleries. Moreover, the association rules extraction model between sites on the one hand and germs on the other hand was used for sampling. Results: The study showed that 83% of the samples have been contaminated after biocleaning. The most contaminated services have been men's and women's surgeries. 62% of isolated germs have been identified as Gram-positive bacteria, 29% as Gram-negative bacteria, and 9% as fungi. Concerning the association rules extraction model, a strong association between some contaminated sites and the presence of germ has been found, such as the association between wall and nightstand and door cuff, meaning that the wall and nightstand contamination is systematically linked to that of the door cuff. The disinfection procedure efficacy evaluation has enabled suggesting renewing it each 4 h. Conclusion: Microbiological monitoring of surfaces is necessary at hospital level through the use of the association rule extraction model, which is very important to optimize the sampling, cleaning, and disinfection site scenarios of the most contaminated ones.


Asunto(s)
Microbiología Ambiental , Monitoreo del Ambiente , Hospitales , Desinfección/normas , Monitoreo del Ambiente/métodos , Femenino , Humanos , Masculino , Marruecos
10.
J Cancer Res Ther ; 17(2): 551-555, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34121707

RESUMEN

BACKGROUND: The coronavirus disease 2019 (COVID 19) is a zoonotic viral infection that originated in Wuhan, China, in December 2019. It was declared a pandemic by the World Health Organization shortly thereafter. This pandemic is going to have a lasting impact on the functioning of pathology laboratories due to the frequent handling of potentially infectious samples by the laboratory personnel. To deal with this unprecedented situation, various national and international guidelines have been put forward outlining the precautions to be taken during sample processing from a potentially infectious patient. PURPOSE: Most of these guidelines are centered around laboratories that are a part of designated COVID 19 hospitals. However, proper protocols need to be in place in all laboratories, irrespective of whether they are a part of COVID 19 hospital or not as this would greatly reduce the risk of exposure of laboratory/hospital personnel. As part of a laboratory associated with a rural cancer hospital which is not a dedicated COVID 19 hospital, we aim to present our institute's experience in handling pathology specimens during the COVID 19 era. CONCLUSION: We hope this will address the concerns of small to medium sized laboratories and help them build an effective strategy required for protecting the laboratory personnel from risk of exposure and also ensure smooth and optimum functioning of the laboratory services.


Asunto(s)
COVID-19/diagnóstico , Servicios de Laboratorio Clínico/organización & administración , Control de Infecciones/organización & administración , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Centros de Atención Terciaria/organización & administración , COVID-19/epidemiología , COVID-19/transmisión , COVID-19/virología , Instituciones Oncológicas/organización & administración , Instituciones Oncológicas/normas , Servicios de Laboratorio Clínico/normas , Descontaminación/métodos , Descontaminación/normas , Países en Desarrollo , Desinfección/métodos , Desinfección/organización & administración , Desinfección/normas , Hospitales Rurales/organización & administración , Hospitales Rurales/normas , Humanos , India/epidemiología , Control de Infecciones/normas , Personal de Laboratorio Clínico/organización & administración , Personal de Laboratorio Clínico/normas , Pandemias/prevención & control , SARS-CoV-2/aislamiento & purificación , SARS-CoV-2/patogenicidad , Manejo de Especímenes/normas , Centros de Atención Terciaria/normas , Recursos Humanos/organización & administración , Recursos Humanos/normas
11.
Viruses ; 13(6)2021 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-34073735

RESUMEN

Several of the human-pathogenic arenaviruses cause hemorrhagic fever and have to be handled under biosafety level 4 conditions, including Lassa virus. Rapid and safe inactivation of specimens containing these viruses is fundamental to enable downstream processing for diagnostics or research under lower biosafety conditions. We established a protocol to test the efficacy of inactivation methods using the low-pathogenic Morogoro arenavirus as surrogate for the related highly pathogenic viruses. As the validation of chemical inactivation methods in cell culture systems is difficult due to cell toxicity of commonly used chemicals, we employed filter devices to remove the chemical and concentrate the virus after inactivation and before inoculation into cell culture. Viral replication in the cells was monitored over 4 weeks by using indirect immunofluorescence and immunofocus assay. The performance of the protocol was verified using published inactivation methods including chemicals and heat. Ten additional methods to inactivate virus in infected cells or cell culture supernatant were validated and shown to reduce virus titers to undetectable levels. In summary, we provide a robust protocol for the validation of chemical and physical inactivation of arenaviruses in cell culture, which can be readily adapted to different inactivation methods and specimen matrices.


Asunto(s)
Arenavirus/fisiología , Desinfección/métodos , Inactivación de Virus , Animales , Técnicas de Cultivo de Célula , Línea Celular , Células Cultivadas , Chlorocebus aethiops , Desinfección/normas , Humanos , Reproducibilidad de los Resultados , Manejo de Especímenes/métodos , Células Vero
12.
Prev Vet Med ; 193: 105388, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34098231

RESUMEN

Classical scrapie is a prion disease of small ruminants, the infectious agent of which has been shown to be extremely persistent in the environment. Cleaning and disinfection (C&D) after a scrapie outbreak is currently recommended by many governments' veterinary advisors and implemented in most farms affected. Yet, the effectiveness of these procedures remains unclear. The aim of this study was to review existing literature and guidelines regarding farm C&D protocols following classical scrapie outbreaks and assess their effectiveness and the challenges that translation of policy and legislative requirements present at a practical level. A review of the literature was conducted to identify the on-farm C&D protocols used following outbreaks of scrapie, assess those materials with high risk for persistence of the scrapie agent on farms, and review the existing evidence of the effectiveness of recommended C&D protocols. An expert workshop was also organised in Great Britain (GB) to assess: the decision-making process used when implementing C&D protocols on GB farms, the experts' perceptions on the effectiveness of these protocols and changes needed, and their views on potential recommendations for policy and research. Outputs of the literature review revealed that the current recommended protocol for C&D [1 h treatment with sodium hypochlorite containing 20,000 ppm free chlorine or 2 M sodium hydroxide (NaOH)] is based on laboratory experiments. Only four field farm experiments have been conducted, indicating a lack of data on effectiveness of C&D protocols on farms by the re-occurrence of scrapie infection post re-stocking. Recommendations related to the control of outdoor environment, which are difficult and expensive to implement, vary between countries. The expert workshop concluded that there are no practical, cost-effective C&D alternatives to be considered at this time, with control therefore based on C&D only in combination with additional time restrictions on re-stocking and replacement with non-susceptible livestock or more genetically resistant types, where available. Participants agreed that C&D should still be completed on scrapie affected farms, as it is considered to be "good disease practice" and likely to reduce the levels of the prion protein. Participants felt that any additional protocols developed should not be "too prescriptive" (should not be written down in specific policies) because of significant variation in farm types, farm equipment and installations. Under this scenario, control of classical scrapie on farms should be designed with a level of C&D in combination with re-stocking temporal ban and replacement with livestock of limited susceptibility.


Asunto(s)
Brotes de Enfermedades , Desinfección/normas , Priones , Scrapie , Enfermedades de las Ovejas , Animales , Brotes de Enfermedades/prevención & control , Brotes de Enfermedades/veterinaria , Guías como Asunto , Scrapie/epidemiología , Scrapie/prevención & control , Ovinos , Enfermedades de las Ovejas/epidemiología , Reino Unido/epidemiología
13.
J Occup Environ Hyg ; 18(6): 265-275, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33989113

RESUMEN

The COVID-19 pandemic has caused a high demand for respiratory protection among health care workers in hospitals, especially surgical N95 filtering facepiece respirators (FFRs). To aid in alleviating that demand, a survey of commercially available filter media was conducted to determine whether any could serve as a substitute for an N95 FFR while held in a 3D-printed mask (Stopgap Surgical Face Mask from the NIH 3D Print Exchange). Fourteen filter media types and eight combinations were evaluated for filtration efficiency, breathing resistance (pressure drop), and liquid penetration. Additional testing was conducted to evaluate two filter media disinfection methods in the event that the filters were reused in a hospital setting. Efficiency testing was conducted in accordance with the procedures established for approving an N95 FFR. One apparatus used a filter-holding device and another apparatus employed a manikin head to which the 3D-printed mask could be sealed. The filter media and combinations exhibited collection efficiencies varied between 3.9% and 98.8% when tested with a face velocity comparable to that of a standard N95 FFR at the 85 L min-1 used in the approval procedure. Breathing resistance varied between 10.8 to >637 Pa (1.1 to > 65 mm H2O). When applied to the 3D-printed mask efficiency decreased by an average of 13% and breathing resistance increased 4-fold as a result of the smaller surface area of the filter media when held in that mask compared to that of an N95 FFR. Disinfection by dry heat, even after 25 cycles, did not significantly affect filter efficiency and reduced viral infectivity by > 99.9%. However, 10 cycles of 59% vaporized H2O2 significantly (p < 0.001) reduced filter efficiency of the media tested. Several commercially available filter media were found to be potential replacements for the media used to construct the typical cup-like N95 FFR. However, their use in the 3D-printed mask demonstrated reduced efficiency and increased breathing resistance at 85 L min-1.


Asunto(s)
COVID-19/prevención & control , Desinfección/normas , Contaminación de Equipos/prevención & control , Ensayo de Materiales/normas , Respiradores N95/virología , Exposición Profesional/prevención & control , Pandemias/prevención & control , Contaminantes Ocupacionales del Aire/análisis , Análisis de Falla de Equipo/estadística & datos numéricos , Guías como Asunto , Humanos , Exposición por Inhalación/análisis , SARS-CoV-2
14.
Antimicrob Resist Infect Control ; 10(1): 77, 2021 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-33971944

RESUMEN

BACKGROUND: Healthcare-associated infections (HAIs) are a significant cause of morbidity and mortality in hospitalized patients. Water in the environment can be a source of infection linked to outbreaks and environmental transmission in hospitals. Water safety in hospitals remains a challenge. This article has summarized available scientific literature to obtain an overview of outbreaks linked to water-containing hospital equipment and strategies to prevent such outbreaks. METHODS: We made a list of water-containing hospital equipment and devices in which water is being used in a semi-closed circuit. A literature search was performed in PubMed with a search strategy containing the names of these medical devices and one or more of the following words: outbreak, environmental contamination, transmission, infection. For each medical device, we summarized the following information: the function of the medical device, causes of contamination, the described outbreaks and possible prevention strategies. RESULTS: The following water-containing medical equipment  or devices were identified: heater-cooler units, hemodialysis equipment, neonatal incubators, dental unit waterlines, fluid warmers, nebulizers, water traps, water baths, blanketrol, scalp cooling, and thermic stimulators. Of the latter three, no literature could be found. Of all other devices, one or more outbreaks associated with these devices were reported in the literature. CONCLUSIONS: The water reservoirs in water-containing medical devices can be a source of microbial growth and transmissions to patients, despite the semi-closed water circuit. Proper handling and proper cleaning and disinfection can help to reduce the microbial burden and, consequently, transmission to patients. However, these devices are often difficult to clean and disinfect because they cannot be adequately opened or disassembled, and the manufacturer's cleaning guidelines are often not feasible to execute. The development of equipment without water or fluid containers should be stimulated. Precise cleaning and disinfection guidelines and instructions are essential for instructing healthcare workers and hospital cleaning staff to prevent potential transmission to patients.


Asunto(s)
Infección Hospitalaria/epidemiología , Contaminación de Equipos , Abastecimiento de Agua , Infección Hospitalaria/prevención & control , Brotes de Enfermedades , Desinfección/normas , Contaminación de Equipos/prevención & control , Equipos y Suministros de Hospitales , Humanos , Control de Infecciones
15.
PLoS One ; 16(4): e0250455, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33886664

RESUMEN

Stethoscopes have been suggested to be a possible vector of contact transmission. However, only a few studies have focused on the prevalence of contamination by multidrug-resistant (MDR) bacteria and effectiveness of disinfection training to reduce. This study is to investigate the burden of stethoscope contamination with nosocomial pathogens and multidrug-resistant (MDR) bacteria and to analyze habit changes in disinfection of stethoscopes among healthcare workers (HCWs) before and after education and training. We performed a prospective pre and post quasi-experimental study. A total of 100 HCWs (55 doctors and 45 nurses) were recruited. HCWs were surveyed on their disinfection behavior and stethoscopes were cultured by pressing the diaphragm directly onto a blood agar plate before and after education on disinfection. Pulsed-field gel electrophoresis was performed to determine the relatedness of carbapenem-resistant Enterobacteriaceae. Most of the stethoscopes were contaminated with microorganisms before and after the intervention (97.9% and 91.5%, respectively). The contamination rate of stethoscopes with nosocomial pathogens before and after education was 20.8% and 19.2%, respectively. Stethoscope disinfection habits improved (55.1% vs 31.0%; p<0.001), and the overall bacterial loads of contamination were reduced (median colony-forming units, 15 vs 10; p = 0.019) after the intervention. However, the contamination rate by nosocomial pathogens and MDR bacteria did not decrease significantly. A carbapenemase-producing Klebsiella pneumoniae isolates from a stethoscope was closely related to isolates from the patients admitted at the same ward where the stethoscope was used. Stethoscopes were contaminated with various nosocomial pathogens including MDR bacteria and might act as a vehicle of MDR bacteria. Continuous, consistent education and training should be provided to HCWs using multifaceted approach to reduce the nosocomial transmission via stethoscopes.


Asunto(s)
Infección Hospitalaria/microbiología , Enterobacteriaceae/efectos de los fármacos , Klebsiella pneumoniae/efectos de los fármacos , Estetoscopios/microbiología , Adulto , Carbapenémicos/farmacología , Infección Hospitalaria/epidemiología , Infección Hospitalaria/prevención & control , Desinfección/normas , Contaminación de Medicamentos , Farmacorresistencia Bacteriana Múltiple/genética , Enterobacteriaceae/patogenicidad , Contaminación de Equipos/prevención & control , Femenino , Personal de Salud , Humanos , Klebsiella pneumoniae/patogenicidad , Masculino , Persona de Mediana Edad , Médicos , Estudios Prospectivos
16.
J Vasc Surg Venous Lymphat Disord ; 9(4): 1025-1030, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33737261

RESUMEN

Recently reported guidelines from the Society of Diagnostic Medical Sonography regarding disinfection of ultrasound probes and infection control policies for ultrasound procedures conflict with accepted clinical norms in vein practices and recommendations from the American Institute for Ultrasound in Medicine. We have provided a review of these conflicting policy recommendations and new proposed practice recommendations and a call for physicians who perform ultrasound-guided procedures to be involved in the process of development and critical review of societal recommendations.


Asunto(s)
Control de Infecciones/normas , Guías de Práctica Clínica como Asunto/normas , Ultrasonografía/instrumentación , Venas/diagnóstico por imagen , Desinfección/métodos , Desinfección/normas , Contaminación de Equipos/prevención & control , Geles , Humanos , Control de Infecciones/métodos , Transductores
17.
J Hosp Infect ; 112: 37-41, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33766544

RESUMEN

This study investigated the potential of olanexidine gluconate as environmental disinfectant against enveloped viruses in the suspension test and three non-porous surface tests. In the suspension test, olanexidine gluconate showed immediate virucidal activity. In addition, non-porous surface tests demonstrated that, although the immediate effect of aqueous formulations was weak, the final virucidal efficacy outcompeted that of ethanol for disinfection. Furthermore, the effectiveness of olanexidine gluconate persisted even after drying on environmental surfaces. This study demonstrated the potential usage of olanexidine gluconate formulations as an environmental disinfectant in the infection control of enveloped viruses.


Asunto(s)
Biguanidas/farmacología , Desinfectantes/farmacología , Glucuronatos/farmacología , Control de Infecciones/métodos , Envoltura Viral/efectos de los fármacos , Virus/efectos de los fármacos , Biguanidas/química , Línea Celular , Desinfectantes/química , Desinfección/normas , Microbiología Ambiental , Glucuronatos/química , Humanos , Pruebas de Sensibilidad Microbiana , Virus/clasificación
18.
GMS J Med Educ ; 38(1): Doc22, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33659627

RESUMEN

Introduction: The corona virus pandemic rendered most live education this spring term impossible. Many classes were converted into e-learning formats. But not all learning content and outcomes can readily be transferred into digital space. Project outline: Emergency medicine teaching relies on hands-on simulation training. Therefore, we had to devise a catalogue of measures, that would enable us to offer simulation training for Advanced Life Support. Summary of work: Strict hygienic rules including disinfection of hands, wearing personal protective gear at all times and disinfection of equipment were implemented. Group size and number of staff was reduced, introducing fixed student teams accompanied by the same teacher. Only large rooms with good ventilation were used. Under these conditions, we were allowed to carry out core Advanced Life Support simulations. Other content had to be transferred to online platforms. Discussion: Heeding general hygiene advise and using personal protective gear, a central cluster of simulations was carried out. Students and staff adhered to rules without complaint. No infections within faculty or student body were reported. Conclusion: It seems feasible to conduct core simulations under strict hygienic protocol.


Asunto(s)
COVID-19/epidemiología , Educación de Postgrado en Medicina/organización & administración , Medicina de Emergencia/educación , Distanciamiento Físico , Desinfección/normas , Desinfección de las Manos/normas , Humanos , Naftoquinonas , Pandemias , Equipo de Protección Personal/provisión & distribución , Piranos , SARS-CoV-2
19.
J Hosp Infect ; 112: 27-30, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33771601

RESUMEN

In the ongoing SARS CoV-2 pandemic, effective disinfection measures are needed, and guidance based on the methodological framework of the European Committee for Standardization (CEN) may enable the choice of effective disinfectants on an immediate basis. This study aimed to elucidate whether disinfectants claiming 'virucidal activity against enveloped viruses' as specified in the European Standard EN 14476 as well as in the German Association for the Control of Viral Diseases/Robert Koch Institute (DVV/RKI) guideline are effectively inactivating SARS-CoV-2. Two commercially available formulations for surface disinfection and one formulation for hand disinfection were studied regarding their virucidal activity. Based on the data of this study the enveloped SARS-CoV-2 is at least equally susceptible compared to the standard test virus vaccinia used in the EN 14476 and DVV/RKI guidelines. Thus, chemical disinfectants claiming 'virucidal activity against enveloped viruses' based on the EN 14476 and DVV/RKI guidelines will be an effective choice to target enveloped SARS-CoV-2 as a preventive measure.


Asunto(s)
Antivirales/farmacología , Desinfectantes/farmacología , Desinfección/normas , Desinfección de las Manos/normas , SARS-CoV-2/efectos de los fármacos , Antivirales/química , COVID-19/prevención & control , Desinfectantes/química , Desinfección/clasificación , Desinfección de las Manos/métodos , Humanos , Virosis/prevención & control
20.
Antimicrob Resist Infect Control ; 10(1): 25, 2021 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-33516268

RESUMEN

CONTEXT: In the emergency ward, where the use of ultrasound is common (including for sterile procedures), ward equipment is constantly exposed to high risks of microbiological contamination. There are no clear guidelines for disinfection control practices in emergency departments, and it is not known how emergency ward doctors follow good hygiene practices. METHOD: A multi-centre audit was conducted in 16 emergency services from Northern France regional hospitals, in form of a questionnaire. It was proposed to all emergency ward physicians. We excluded questionnaires when physicians mentioned that they did not use ultrasound on a daily basis. The questionnaire was designed using existing hygiene and ultrasound disinfection practices guidelines from varying French medical societies. It included three different clinical scenarios: (a) ultrasound on healthy skin, (b) on injured skin, and (c) ultrasound-guided punctures. All questions were closed-ended, with only one answer corresponding to the guidelines. We then calculated compliance rates for each question, each clinical situation, and an overall compliance rate for all the questions. RESULTS: 104 questionnaires were collected, and 19 were excluded. For the 85 analysed questionnaires, the compliance rates were 60.4% 95% CI [56.4-64.7] for ultrasound on healthy skin, 70.9% 95% CI [66.3-76.1] on injured skin and 69.4% 95% CI [65.1-73.6] for ultrasound-guided punctures. The overall compliance rate for the compliance questions was 66.1% 95% CI [62.8-69.1]. Analysis of the questionnaires revealed severe asepsis errors, misuse of gel, ignorance of infection control practices to be applied in the context of ultrasound-guided puncture and exposure of the probe to body fluids. CONCLUSION: This study details areas for quality improvement in the disinfection of emergency ultrasound scanner use. Consequently, we propose a standardized protocol based upon the recommendations used for the questionnaire drafting, with a visual focus on the low compliance points that have been revealed in this audit. This protocol has been distributed to all the medical emergency services audited and included in the emergency resident's ultrasound learning program.


Asunto(s)
Desinfección/normas , Servicio de Urgencia en Hospital/normas , Adhesión a Directriz/estadística & datos numéricos , Higiene/normas , Auditoría Clínica , Infección Hospitalaria/prevención & control , Contaminación de Equipos/prevención & control , Francia , Humanos , Encuestas y Cuestionarios , Ultrasonografía/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...